Operative Techniques in Orthopaedics
Volume 18, Issue 3 , Pages 196-203, July 2008

Measurement of Knee Laxity and Pivot-Shift Kinematics With Magnetic Sensors

  • Andrew A. Amis, DSc(Eng)

      Affiliations

    • Mechanical Engineering and Musculoskeletal Surgery Departments, Imperial College London, London, United Kingdom
    • Corresponding Author InformationAddress reprint requests to Andrew A. Amis, DSc(Eng), Mechanical Engineering Department, Imperial College London, London SW7 2AZ, UK
  • ,
  • Pierluigi Cuomo, MD

      Affiliations

    • Orthopaedics Clinic, University of Florence, Florence, Italy
  • ,
  • Reddi Boddu Siva Rama, MD

      Affiliations

    • Mechanical Engineering and Musculoskeletal Surgery Departments, Imperial College London, London, United Kingdom
  • ,
  • Francesco Giron, MD

      Affiliations

    • Orthopaedics Clinic, University of Florence, Florence, Italy
  • ,
  • Anthony M.J. Bull, PhD

      Affiliations

    • Bioengineering Department, Imperial College London, London, United Kingdom
  • ,
  • Rhidian Thomas, MSurg

      Affiliations

    • Orthopaedic Surgery Department, Charing Cross Hospital, London, United Kingdom
  • ,
  • Paolo Aglietti, MD

      Affiliations

    • Orthopaedics Clinic, University of Florence, Florence, Italy

This article describes work to develop a system to measure translational and rotational knee laxity and complex “dynamic” tests, such as the pivot-shift test, by the use of electromagnetic sensors mounted onto the limb segments with specially developed splints and clamps. We have measured in vitro and in vivo the motion of bone-mounted sensors versus skin-mounted sensors, and thus shown that there was an overall accuracy of approximately ±1 mm in translation and ±1° in rotation when the movements were relatively slow. It was found that, for clinical pivot-shift testing, the dynamic motion led to inaccuracy because of the inertia of the sensor mounting system, which led to the peaks of the sudden reduction motions not being measured; this system requires further development. We show that it also is possible to use this system in the clinic to record both rotational and translational knee laxity motions, both of which are integral to the pivot-shift instability. The force and torque were applied to the limb with sets of constant-force springs, which allowed the knee to be flexed while maintaining a constant load across the knee. This maneuver led to graphs showing the limits of translation and rotation laxity, across the range of knee flexion, for a series of 60 patients. It was then shown that the pivot-shift motion occurred within these laxity limits. The level of measurement accuracy means that the system described should be clinically useful.

Keywords: anterior cruciate ligament, knee instability, ligament laxity measurement, pivot shift, electromagnetic motion sensors

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1048-6666(09)00011-1

doi:10.1053/j.oto.2008.12.010

Operative Techniques in Orthopaedics
Volume 18, Issue 3 , Pages 196-203, July 2008